1.The large screen liquid crystal display,English menu.
2.The use of German imports of infrared detector, O2 sensor, vibration resistance, good stability, high precision.
3.The measurement of CO, HC, CO2 ,O2, COcor concentration and the lambda value, speed, temperature, flow, pressure.
4.With the single, double idle idle, general measuring function.
5.It can be measured with diesel, gasoline, LPG, CNG and alcohol as a fuel for vehicle. 6.According to the new standard and the United States BAR97standards development, in line with the ISO3930or OIMLR99 I level precision.
7.With the automatic zero adjustment, automatic cleaning, automatic temperature compensation, pressure compensation.
8.With the HC residue measurement, traffic monitoring, gas leak check.
9.The machine has self diagnostic function, fault when prompted, until the troubleshooting can continue measurement.
10. With speed, temperature measurement, built-in printer(or the analog output interface or RS -232A digital serial communication interface) or digital (Analog ) interface network.
11.The license plate number input and 2000 groups of data storage, reference function, clock display.
Item |
Date |
Measuring range |
HC:0~10000×10-6(ppm)vol CO:0~10×10-2(%)vol CO2:0~20×10-2(%)vol O2:0~25×10-2(%)vol R.M.P: 0-9999r.m.p OIL TEMP:0-150℃ Lambda: 0.5~1.5 COcor:010×10-2(%)vol |
Indication error |
HC ± 12×10-6(ppm) vol (absolute error)or± 5% (relative error) CO± 0.06×10-2(%) vol (absolute error)or± 5% (relative error) CO2 ±0.5×10-2 (%) vol (absolute error)or± 5% (relative error) O2 ±0.1×10-2(%) vol (absolute error)or± 5% (relative error) |
Repeatability |
Repetition error≤+/- 2% |
Stability |
Automatic zero, volume moments drift ≤ ± 3% |
Resolution |
HC:1×10-6(ppm)vol CO:0.01×10-2(%) vol CO2:0.1×10-2(%) vol O2:0.01×10-2(%) vol Lambda: 0.01 R.P.M:10r.p.m, OIL TEMP:0.1℃ |
Response time |
95% repose time no more than 10 seconds |
Warm up time |
8min ( Emergency detection can be preheated 3 min ) |
Output Mode |
Digital direct-reading show gases ,can be attached printer to print name,the maximum, average and minimum concentration, can test time, date, etc.Can be attached to interface with the computer network.
|
Environmental conditions |
Temperature-5 ~ 50 ℃, relative humidity ≤90% |
Power |
AC100-240V 50/60Hz or DC12V (Choose add power inverter) Consumption Power 40VA |
Dimensions (with bracket) |
420mm (L) x 310mm (W) x 170mm (H) |
Weight |
About 9kg |