SV-5Q Automatic Car Emission Exhaust Gas Analyzer is measurable with liquefied gas (LG), liquefied natural gas (LNG), gasoline and diesel or other alternative fuel vehicles. SV-5Q Automatic Car Emission Exhaust Gas Analyzer is equipped with Built-in printer
1. SV-5Q Automatic Car Emission Exhaust Gas Analyzer is used to measure the concentration of HC, CO, CO2, O2, NO in the Automobile Exhaust Gas.
2. Two kinds of test function: General and Two-speed idle
3. Full English Menu Operation
4. LCD (liquid crystal) screen displays
5. Auto-zeroing
6. Automatic calculation and show the air-fuel ratio λ
7. Equipped with RS232 digital serial communication interface to facilitate networking
8. Optional function: rotate speed and oil temperature measurement
9. Equipped with functions of Plate number and time display
10. Can store and search 500 groups of data, built-in printer
11. Measurable with liquefied gas (LG), liquefied natural gas (LNG) and gasoline and other alternative fuel vehicles.
Measurement Range |
CO |
0~10×10-2 (%)vol |
||
CO2 |
0~20×10-2 (%)vol |
|||
HC |
0~10000×10-6 (ppm)vol |
|||
O2 |
0~25×10-2 (%)vol |
|||
NO |
0~40000×10-6 (ppm)vol |
|||
Indication Error |
|
Absolute error |
Relative error |
|
CO |
±0.06×10-2(%)vol |
±5% |
||
CO2 |
±0.5×10-2(%)vol |
±5% |
||
HC |
±12×10-6 vol |
±5% |
||
O2 |
±0.1×10-2(%)vol |
±5% |
||
NO |
±25×10-6 vol |
±4% |
||
Preheating Time |
10 min.(3 min. warm-up for fast measurement) |
|||
Environmental condition |
Temperature |
-5~40 centigrade |
||
Humidity |
no more than 85% |
|||
Atmospheric pressure |
86~106kPa |
|||
Power |
AC 220V±10%; 50 Hz±1Hz |
|||
Gross Weight |
9.8kg |
|||
Packing Size |
420*320*250(mm) |