1. KCT Series Portable Paint Coating Thickness Gauge Measurement Range :
KCT100 Measurement Range: 0—6000um
KCT100A Measurement Range: 0—6000um
KCT200 Measurement Range: 0—1250um or 0—50mil
2. Accuracy:± [(1%~3%)H+1um] Note:H is thickness reading
3. powers down after 60 seconds of no activity.
1. Power-on and Warm-up
Keystroke once;Wait until READY! is displayed on the LCD. Now the gauge is ready for measurements.
2. Zeroing
Keystroke twice; when BASE ZERO is displayed, place flat on Fe or Al base; hold steady. After measurement is obtained, DONE is shown and gauge beeps. Then lift gauge.
Note: Please conduct zeroing process after changing base. Zeroing process could be repeated for better results.
3. Unit Change
Keystroke three times; convert from ums to mils or vice versa.
4. Reset
Keystroke four times,Wait until RESET is displayed; after gauge resets, users can conduct zeroing process if necessary.
Materials
Gauge Reference Fe and Al Base
Certified Plastic Shim Battery etc.
|
KCT100 |
KCT200 |
KCT100A |
Working principle |
Magnetic |
Magnetic & Eddy |
Eddy |
Substrate |
FE base |
FE & NFE base - dual use |
FE base |
Resolution |
1um |
||
Min. measuring area |
Φ15mm |
||
Accuracy |
±[(1%~3%)H+1um] Note: H is thickness reading |
||
Min. curvature |
Convex radius: 5mm Concave radius: 25mm |
||
Min thickness of substrate |
Fe:0.2mm NFE:0.05mm |
||
Working temperature |
-10℃~60℃ |
||
Power |
AAA battery 4 pcs |
||
Weight |
82g |
||
Size |
112*69*28mm |